With this gauss meter it is possible to measure magnetic fields up to 2000 mG directly. At the same time, the gauss meter shows the strength of the magnetic field numerically using an X, Y and Z axis. Another measuring function of the gauss meter is the electromagnetic field strength measurement. With this measuring function in the gauss meter, the electromagnetic field strength on supply lines can be determined at a frequency of 50/60 Hz. It is also possible to carry out measurements in the high frequency range with the gauss meter. Thus, measurements can be carried out with the gauss meter on, for example, a WLAN router or a mobile phone. Because of its many measuring functions, the gauss meter is a compact and multifunctional measuring device.
In addition to the numerical display on the gauss meter, a graphical progression of the last 20 measured values is also displayed. The measured value is also displayed as a bar diagram by the gauss meter. This bar chart on the gauss meter is divided into three traffic light colors. As soon as the measured value exceeds a fixed value, so that the bar chart on the gauss meter has reached the red area, an acoustic alarm is activated. This alarm on the gauss meter switches off automatically as soon as the measured value is below the fixed limit threshold.
All three measurement modes can be read off simultaneously on the 2.4'' TFT display of the gauss meter. Switching between the individual measurement modes on the gauss meter is therefore not necessary. The background lighting of the gauss meter can be adjusted in 4 levels. Thus, the display of the gauss meter can be adapted to the most varied of environmental conditions at the touch of a button.
Low Frequency Magnetic Field – Unit µT | ||
Measuring Range | 0.01 µT, 0.1 µT | ± 12% + 5 digits at 50/60 Hz |
Low Frequency Magnetic Field – Unit mG | ||
Measuring Range | 0.1 mG, 1 mG | ± 12% + 5 digits at 50/60 Hz |
Low Frequency Electromagnetic Field – Unit V/m | ||
Measuring Range | 1V / m | ± 7% + 20 digits at 50/60 Hz |
High Frequency Electromagnetic Field – Unit mV/m, V/m | ||
Measuring Range | 0.01, 0.1 mV / m | 1.0 dB at 1V / m, 900 MHz |
High Frequency – Unit µW / cm² | ||
Measuring Range | 0.01, 0.1 µW / cm² | |
High Frequency – Unit µW / m², mW / m² | ||
Measuring Range | 0.1, 1 µW / m² / 0.1 mW / m² | |
High Frequency – Unit mA / m | ||
Measuring Range | 0.01, 0.1-mA / m | |
Environmental Specifications | ||
Operating Temperature | 23 ± 5°C / 73.4 ± 9°F | |
Humidity Range | 25 ... 75% RH | |
RF Field Strength | < 3V / m and 30 MHz | |
Other Specifications | ||
Bandwidth | High frequency: 50 MHz ... 3.5 GHz / Low frequency: 50/60 Hz | |
Number of Sensors | Magnetic field: 3 / Electromagnetic field: 1 | |
Measuring Rate | 1 Hz | |
Over Range Display | "- - - -" | |
Storage | MIN / MAX memory | |
Display | 2.4" TFT | |
Power Supply | 3 x 1.5V AAA batteries | |
Power Consumption | Approx. 24 ... 38-mA | |
Automatic Shutdown | After 10 minutes (Function can be switched off) | |
Operating Conditions | 0 ... 50°C / 32 ... 122°F, < 80% RH | |
Dimensions | 107 x 60 x 25 mm / 4.2 x 2.4 x 1 in | |
Weight | Approx. 106 g / < 1 lb (without batteries) |