Clamp Meter PCE-DC 25

SKU : PCE-DC 25
Category : Clamp Meter

The clamp meter has a measuring range of 0… 1000 A AC/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.

Clamp meter with Bluetooth interface / Current measurement 0 ... 1000 A AC/DC / Temperature measurement / NCV test / Clamp opening 34 mm (1.3") / Measuring rate of 3 Hz / Optionally expandable with Rogowski coil for 3000 A AC / Automatic switch-off

The clamp meter has a measuring range of 0… 1000 A AC/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.

In addition to current measurement, the clamp meter can also measure voltages from 0… 1000 V AC/DC, resistances, frequencies and capacitances. The functions can be set using the rotary selector switch on the clamp meter. With the NCV function, the clamp meter can be used to determine the absence of voltage without contact. As soon as a voltage of 150 V AC is applied, this is indicated by an additional red LED. This function is active for every measuring function selected using the rotary selector switch. An LED lamp is integrated in the clamp meter for optimal illumination of the measuring point.

The clamp meter can be connected to an Android or iOS device via the Bluetooth interface. With the free app for the clamp meter, the measured values ​​can be displayed, saved and further processed. The clamp meter thus covers a wide range of measuring tasks due to the multitude of functions.

  • Measuring range: 0 ... 1000 A AC/DC
  • Bluetooth interface
  • Inrush current measurement
  • Not Connected Voltage function
  • LC colour display
  • Optionally with ISO certificate
Technical Specifications
DC Voltage
RangeResolutionAccuracyNotes
600.0 mV0.1 mV±(0.5 % + 8 digits)Input impedance: >10 MΩ
Overvoltage protection: 1000 V AC/DC
6.000 V0.001 V±(1.5 % + 5 digits)
60.00 V0.01 V±(1.5 % + 5 digits)
600.0 V0.1 V±(1.5 % + 5 digits)
1000 V1 V±(1.5 % + 5 digits)
AC Voltage
6.000 V0.001 V±(1.5 % + 5 digits)Peak accuracy: ±10 %
Response time: 1 ms
Input impedance: >10 MΩ
Overvoltage protection: 1000 V AC/DC
60.00 V0.01 V±(1.5 % + 5 digits)
600.0 V0.1 V±(1.5 % + 5 digits)
1000 V1 V±(1.5 % + 5 digits)
Low Pass Filter (LowZ, 50–400 Hz)
6.000 V0.001 V±(3.0 % + 40 digits)Input impedance: <300 kΩ
Overvoltage protection: 1000 V AC/DC
60.00 V0.01 V±(3.0 % + 40 digits)
300.0 V0.1 V±(3.0 % + 40 digits)
AC + DC Voltage (50–400 Hz)
6.000 V0.001 V±(2.5 % + 20 digits)Input impedance: >10 MΩ
60.00 V0.01 V±(2.5 % + 20 digits)
600.0 V0.1 V±(2.5 % + 20 digits)
1000 V1 V±(2.5 % + 20 digits)
Direct Current
600.0 A0.1 A±(2.5 % + 5 digits)Overvoltage protection: 1000 A DC
1000 A1 A±(2.8 % + 5 digits)
Alternating Current (50–60 Hz)
600.0 A0.1 A±(2.5 % + 5 digits)Overload protection: 1000 A AC/DC
1000 A1 A±(2.8 % + 5 digits)
Flexible Clamp (50–400 Hz)
30.00 A0.01 A±(3.0 % + 5 digits)Overload protection: 3000 A AC/DC
300.0 A0.1 A±(3.0 % + 5 digits)
3000 A1 A±(3.0 % + 5 digits)
Resistance
600.0 Ω0.1 Ω±(1.0 % + 10 digits)Overvoltage protection: 1000 V AC/DC
6.000 kΩ0.001 kΩ±(1.5 % + 5 digits)
60.00 kΩ0.01 kΩ±(1.5 % + 5 digits)
600.0 kΩ0.1 kΩ±(1.5 % + 5 digits)
6.000 MΩ0.001 MΩ±(2.5 % + 5 digits)
60.00 MΩ0.01 MΩ±(3.5 % + 10 digits)
Continuity Test
Signal <50 ΩOvervoltage protection: 1000 V AC/DC
Diode Test
Test current <1.5 mAMax open circuit voltage: 3.3 V DC
Frequency Measurement
9.999 Hz ... 99.99 kHz±(1.2 % + 5 digits)Resolution: 0.01 ... 10 Hz
Overvoltage protection: 1000 V AC/DC
Sensitivity: >5 Vrms, duty 20–80%
Duty Cycle
10.0 ... 90.0 %0.1 %±(1.2 % + 8 digits)Pulse: 40 Hz ... 10 kHz
Amplitude: ±5 V (0.1–100 ms)
Capacitance
60.00 nF0.01 nF±(4.0 % + 20 digits)Overvoltage protection: 1000 V AC/DC
600.0 nF0.1 nF±(3.0 % + 8 digits)
6.000 µF0.001 µF±(3.0 % + 8 digits)
60.00 µF0.01 µF±(3.0 % + 8 digits)
600.0 µF0.1 µF±(3.0 % + 8 digits)
6000 µF1 µF±(5.0 % + 8 digits)
60.00 mF0.01 mF±(5.0 % + 20 digits)
100.0 mF0.1 mF±(5.0 % + 20 digits)
Temperature (Type K)
-40 ... 600.0 °C0.1 °C±(1.5 % + 5 digits)Overvoltage protection: 1000 V AC/DC
Specs refer to ambient ±1 °C, stable.
Prolonged measurement may increase value by 2 °C.
600 ... 1000 °C1 °C±(1.5 % + 5 digits)
-40 ... 600.0 °F0.1 °F±(1.5 % + 9 digits)
600 ... 1800 °F1 °F±(1.5 % + 9 digits)
General Specifications
Clamp opening34 mm / 1.3"
NCV>150 V AC
DisplayLC colour display, "OL" overload indicator
Measuring rate3 values/sec
InterfaceBluetooth
Operating conditions5 ... 40 °C / 41 ... 104 °F, <80 % RH non-condensing
Storage conditions-20 ... 40 °C / -4 ... 140 °F, <80 % RH non-condensing
Max working height2000 m / 7000 ft
Power supply3 x 1.5 V AAA batteries
Auto power off15, 30, 45, 60 minutes
Dimensions250 x 80 x 40 mm / 9.8 x 3.1 x 1.5"
Weight365 g / 12.8 oz