Current Clamp PCE-DC 50

SKU : PCE-DC 50
Category : Clamp Meter

The clamp meter PCE-DC 50 is a measuring device for measuring currents of up to 1000 A AC / DC. In addition to current measurement, the clamp can also measure and test voltage, frequency, duty cycle, resistance, continuity test, capacitors and diodes. The enclosure diameter of the clamp is 48 mm. Thus, you can also perform measurements on cables with a large cross-section. Thanks to the NCVD function, it is possible to use the measuring clamp to check contactlessly whether a voltage is applied to a cable.

Current clamp PCE-DC 50
Clamp meter with true rms measurement / AC current measurement / Voltage measurement / Temperature measurement / Bluetooth interface / Rubberized housing / Display hold / Automatic switch-off / Test lead max. 48 mm / Many measuring functions

The clamp meter PCE-DC 50 is a measuring device for measuring currents of up to 1000 A AC / DC. In addition to current measurement, the clamp can also measure and test voltage, frequency, duty cycle, resistance, continuity test, capacitors and diodes. The enclosure diameter of the clamp is 48 mm. Thus, you can also perform measurements on cables with a large cross-section. Thanks to the NCVD function, it is possible to use the measuring clamp to check contactlessly whether a voltage is applied to a cable.

This clamp has an integrated Bluetooth interface. Via this Bluetooth interface a connection to the PC or the smartphone can be established with the measuring pliers. This allows the measured data of the measuring clamp to be stored and analyzed. If the PC does not have a Bluetooth interface to connect the measuring pliers, a suitable Bluetooth adapter is included in the delivery.

Another special feature of the measuring clamp is the measurement of temperatures. Two type-K thermocouples can be connected to the measuring clamp and read out at the same time. Here, temperatures of up to 1000°C / 1832°F can be measured. The housing of the measuring pliers consists of a robust plastic, which is additionally coated with a rubber coating. Thanks to the additional rubber coating, the measuring pliers can easily withstand impacts.

  • Sample rate 2 Hz
  • Cover on the test sockets
  • AC A and AC V measurement
  • Bluetooth interface
  • Cable diameter max. 48 mm
  • Temperature measurement via 2 thermocouples
  • Automatic shutdown
  • Non-contact voltage detection
Current measurement DC A
Measuring range Resolution Accuracy (of rdg.)
500 μA0.01 μA± (1% + 6 digits)
5000 μA0.1 μA± (1% + 6 digits)
50 A0.01 A± (2.5% + 5 digits)
1000 A0.1 A± (2.5% + 30 digits)
Current measurement AC A
Measuring range Resolution Accuracy (of rdg.)
500 μA0.01 μA± (1.5% + 30 digits)
5000 μA0.1 μA± (1.5% + 30 digits)
50 A0.01 A± (2.5% + 30 digits)
1000 A0.1 A± (2.8% + 30 digits)
Note: For AC A measurements, the specification of accuracy refers to the range of 5% to 100% of the measuring range.
Resistivity
Measuring rangeResolutionAccuracy (of rdg.)
500 Ω0.01± (1% + 9 digits)
5 kΩ0.0001± (1% + 5 digits)
50 kΩ0.001± (1% + 5 digits)
500 kΩ0.01± (1% + 5 digits)
5 MΩ0.0001± (3% + 10 digits)
50 MΩ0.001± (3.5% + 10 digits)
Voltage measurement DC V
Measuring rangeResolutionAccuracy (of rdg.)
500 mV0.01 mV± (0.1% + 8 digits)
5 V0.0001 V± (0.1% + 4 digits)
50 V0.001 V± (0.1% + 4 digits)
500 V0.01 V± (0.1% + 4 digits)
600 V0.1 V± (0.5% + 4 digits)
Voltage measurement AC V (50 Hz ... 1000 Hz)
Measuring rangeResolutionAccuracy (of rdg.)
500 mV0.01 mV± (0.8% + 9 digits) (at 50 Hz / 60 Hz)
5 V0.0001 V± (1% + 30 digits)
50 V0.001 V± (1% + 30 digits)
500 V0.01 V± (1% + 30 digits)
600 V0.1 V± (1% + 30 digits)
Note: The accuracy specification for AC V measurements refers to the range of 5% to 100% of the measuring range.
Capacitance measurement
Measuring rangeResolutionAccuracy (of rdg.)
500 nF0.01± (3.5% + 40 digits)
5000 nF0.1± (3.5% + 10 digits)
50 μF0.001± (3.5% + 10 digits)
500 μF0.01± (3.5% + 10 digits)
5 mF0.0001± (5% + 10 digits)
Frequency measurement
Measuring rangeResolutionAccuracy (of rdg.)
50 Hz0.001± (0.3% + 2 digits)
500 Hz0.01± (0.3% + 2 digits)
5 kHz0.0001± (0.3% + 2 digits)
50 kHz0.001± (0.3% + 2 digits)
500 kHz0.01± (0.3% + 2 digits)
5 MHz0.0001± (0.3% + 2 digits)
10 MHz0.001± (0.3% + 2 digits)
Duty cycle
Measuring rangeResolutionAccuracy (of rdg.)
5% ... 95%0.1± (1% + 2 digits) (from the measured value)
Pulse width: 100 μs ... 100 ms
Frequency: 10 Hz ... 10 kHz
Temperature
Measuring rangeResolutionAccuracy (of rdg.)
-100°C ... 1000°C / -148 ... 1832°F0.1± (1% + 2.5°C / 4.5°F)
General technical data
Conductor diameterMax. 48 mm
DisplayTwo lines 50,000 digits
Continuity test50 ohms / < 50-mA
Diode test0.3-mA / 2.8V DC
Battery indicatorBattery icon when battery low
OverrangeOL, if measuring range exceeded
Sample rate2 Hz
InterfaceBluetooth
Peak detection> 1 ms
ThermocoupleType K
Fuse500-mA ceramic quick-acting
AC bandwidth (AC A / AC V)50 Hz ... 400 Hz
AC measurementTrue RMS
Operating conditions5°C ... 40°C / 41 ... 104°F, max. 80% RH at 31°C
Storage conditions-20°C ... 60°C / -4 ... 140°F, max. 80% RH
Power supply9V block battery
Automatic shutdownAfter about 30 minutes
Dimensions (W x H x D)230 x 76 x 40 mm / 9 x 3 x 1.6 in
Weight315 g / < 1 lb
SecurityIEC 1010-1 (2001); EN 61010-1 (2001)
CAT III 600V, CAT II 1000V
Degree of pollution 2