Digital Multimeter PCE-DM 7

SKU : PCE-DM 7
Category : Multimeter

The Digital Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature. Our Digital Multimeter has a hold function for saving measurement results as well as non-contact voltage detection (NCV).

Digital Multimeter / true RMS measurement / temperature measurement / automatic and manual measurement range selection / simple operation / bar graph display

The Digital Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature. Our Digital Multimeter has a hold function for saving measurement results as well as non-contact voltage detection (NCV).

The device enables both automatic and manual measurement range selection and is equipped with an easy-to-read 2.8-inch LCD with backlight. With a sampling rate of three measurements per second, it delivers quick results and switches off automatically after five minutes of inactivity to extend the battery life. In addition, the Digital Multimeter offers a dual display: a bar graph for quick visual assessments and a numerical display for precise readings.

The Digital Multimeter is powered by two 1.5 V batteries and is designed for easy one-handed operation. The compact dimensions of 140 x 70 x 35 mm make the Digital Multimeter a practical tool for everyday use by electricians and hardware developers as well as in other technical applications.

  • Non-contact voltage detection
  • Temperature measurement
  • Automatic power off
  • Automatic and manual measurement range selection
  • Hold function
  • 2.8-inch LC display with backlight
  • Small and compact design
Direct voltage DC
Measurement range up to  0 ... 9,999 mV
Resolution  0,001 mV
Accuracy  ±(0.5 % of Rd +3 digits)
Direct voltage DC
Measurement range up to  10 ... 99,99 mV
Resolution  0,01 mV
Accuracy  ±(0.5 % of Rd +3 digits)
Direct voltage DC
Measurement range up to  100 ... 999,9 mV
Resolution  0,1 mV
Accuracy  ±(0.5 % of Rd +3 digits)
Direct voltage DC
Measurement range up to  1 ... 9,999 V
Resolution  0,001 V
Accuracy  ±(0.5 % of Rd +3 digits)
Direct voltage DC
Measurement range up to  10 ... 99,99 V
Resolution  0,01 V
Accuracy  ±(0.5 % of Rd +3 digits)
Direct voltage DC
Measurement range up to  100 ... 999,9 V
Resolution  0,1 V
Accuracy  ±(0.5 % of Rd +3 digits)
Direct current DC
Measurement range up to  0 ... 9999 µA
Resolution  1 µA
Accuracy  ±(0.8 % of Rd +3 digits)
Direct current DC
Measurement range up to  10 ... 99,99 mA
Resolution  0,01 mA
Accuracy  ±(0.8 % of Rd +3 digits)
Direct current DC
Measurement range up to  100 ... 999,9 mA
Resolution  0,1 mA
Accuracy  ±(1 % of Rd +3 digits)
Direct current DC
Measurement range up to  1 ... 9,999 A
Resolution  0,001 A
Accuracy  ±(1 % of Rd +3 digits)
Capacity
Measurement range up to  0 ... 9,999 nF
Resolution  0,001 nF
Accuracy  ±(5.0 % of Rd +20 digits)
Capacity
Measurement range up to  10 ... 99,99 nF
Resolution  0,01 nF
Accuracy  ±(2.0 % of Rd +5 digits)
Capacity
Measurement range up to  100 ... 999,9 nF
Resolution  0,1 nF
Accuracy  ±(2.0 % of Rd +5 digits)
Capacity
Measurement range up to  1 ... 9,999 µF
Resolution  0,001 µF
Accuracy  ±(2.0 % of Rd +5 digits)
Capacity
Measurement range up to  10 ... 99,99 µF
Resolution  0,01 µF
Accuracy  ±(2.0 % of Rd +5 digits)
Capacity
Measurement range up to  100 ... 999,9 µF
Resolution  0,1 µF
Accuracy  ±(2.0 % of Rd +5 digits)
Capacity
Measurement range up to  1 ... 9,999 mF
Resolution  0,001 mF
Accuracy  ±(5.0 % of Rd +5 digits)
AC voltage
Measurement range up to  0 ... 9,999 mV
Resolution  0,001 mV
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
AC voltage
Measurement range up to  10 ... 99,99 mV
Resolution  0,01 mV
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
AC voltage
Measurement range up to  100 ... 999,9 mV
Resolution  0,1 mV
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
AC voltage
Measurement range up to  1 ... 9,999 V
Resolution  0,001 V
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
AC voltage
Measurement range up to  10 ... 99,99 V
Resolution  0,01 V
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
AC voltage
Measurement range up to  100 ... 750 V
Resolution  0,1 V
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
Alternating current AC
Measurement range up to  0 ... 9999 µA
Resolution  1 µA
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
Alternating current AC
Measurement range up to  10 ... 99,99 mA
Resolution  0,01 mA
Accuracy  ±(1 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
Alternating current AC
Measurement range up to  100 ... 999,9 mA
Resolution  0,1 mA
Accuracy  ±(1.2 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
Alternating current AC
Measurement range up to  1 ... 9,999 A
Resolution  0,001 A
Accuracy  ±(1.2 % of Rd +3 digits)
Frequency range  40 ... 1000 Hz
Resistance
Measurement range up to  0 ... 99,99 Ω
Resolution  0,01 Ω
Accuracy  ±(1 % of Rd +3 digits)
Resistance
Measurement range up to  100 ... 999,9 Ω
Resolution  0,1 Ω
Accuracy  ±(0.5 % of Rd +3 digits)
Resistance
Measurement range up to  1 ... 9,999 kΩ
Resolution  0,001 kΩ
Accuracy  ±(0.5 % of Rd +3 digits)
Resistance
Measurement range up to  10 ... 99,99 kΩ
Resolution  0,01 kΩ
Accuracy  ±(0.5 % of Rd +3 digits)
Resistance
Measurement range up to  100 ... 999,9 kΩ
Resolution  0,1 kΩ
Accuracy  ±(0.5 % of Rd +3 digits)
Resistance
Measurement range up to  1 ... 9,999 M Ω
Resolution  0,001 M Ω
Accuracy  ±(1.5 % of Rd +3 digits)
Resistance
Measurement range up to  10 ... 99,99 M Ω
Resolution  0,01 M Ω
Accuracy  ±(3.0 % of Rd +5 digits)
Duty cycle
Measurement range up to  1 ... 99 %
Resolution  0,1 %
Accuracy  ±(0.1 % of Rd +2 digits)
Frequency
Measurement range up to  0 ... 99,99 Hz
Resolution  0,01 Hz
Accuracy  ±(0.1 % of Rd +2 digits)
Frequency
Measurement range up to  100 ... 999,9 Hz
Resolution  0,1 Hz
Accuracy  ±(0.1 % of Rd +2 digits)
Frequency
Measurement range up to  1 ... 9,999 kHz
Resolution  0,001 kHz
Accuracy  ±(0.1 % of Rd +2 digits)
Frequency
Measurement range up to  10 ... 99,99 kHz
Resolution  0,01 kHz
Accuracy  ±(0.1 % of Rd +2 digits)
Frequency
Measurement range up to  100 ... 999,9 kHz
Resolution  0,1 kHz
Accuracy  ±(0.1 % of Rd +2 digits)
Frequency
Measurement range up to  1 ... 5 MHz
Resolution  0,001 MHz
Accuracy  ±(0.1 % of Rd +2 digits)
Temperature
Measurement range up to  -20 ... +1000 °C
Resolution  1 °C
Accuracy  ±(2.5 % of Rd +5 digits)
Temperature
Measurement range up to  -4 ... +1832 °F
Resolution  1 °F
Accuracy  ±(2.5 % of Rd +5 digits)
General technical data
Measuring functions  HOLD
Display type  LCD with backlight
Display size  2,8 Inch
Measuring rate  3 x per second
Automatic power-off  5 min
Safety standard  CAT II 1000 V, CAT III 600 V
Measurement range selection  Automatic, Manual
Menu language  English, English (GB)
Protection class (device)  IP20
Weight  175 g
Operating conditions  0 ... 40 °C , 0 ... 75 % RH
Storage conditions  -20 ... 60 °C , 0 ... 80 % RH
(Rechargeable) battery  2 x 1,5 V AA battery , Alkali-manganese
Capacity  3000 mAh
Dimensions ( L x W x H )  140 x 70 x 35 mm