The multi-parameter water analysis meter is a mobile measuring device for liquid analysis. This enables the most varied of measurements to be carried out with the multi-parameter water analysis meter. With this multi-parameter water analysis meter, for example, it is possible to determine alkalinity, chlorine, cyanuric acid or the pH value. In order to carry out a measurement with the multi-parameter water analysis meter, a water sample of 10 ml must be placed in a cuvette. The built-in LED in the multi-parameter water analysis meter generates a test light in the wavelength ranges of 503 nm, 570 nm and 620 nm. A photodiode now recognizes the value to be measured based on the light transmission of the sample.
Each measurement is automatically saved by the multi-parameter water analysis meter. The stored measured values can then be read out, for example, via a mobile device via the Bluetooth interface built into the multi-parameter water analysis meter. A free app is available to analyze the measured values from the multi-parameter water analysis meter. It is also possible to establish a Bluetooth connection between the multi-parameter water analysis meter and a computer. Free software is also available for this, with which the measurement data can be analyzed. As another special feature of the multi-parameter water analysis meter, the measurement data can be uploaded to a cloud using both variants and accessed from anywhere. This service for the multi-parameter water analysis meter is also free of charge.
Chlorine | ||
---|---|---|
Measuring range | 0.00 … 2.00 mg/l 2.00 … 3.00 mg/l 3.00 … 4.00 mg/l 4.00 … 8.00 mg/l | |
Accuracy | 0.10 mg/l 0.23 mg/l 0.75 mg/l 1.00 mg/l | |
Resolution | 0.01 mg/l | |
pH | ||
Measuring range | 6.50 ... 8.40 pH | |
Accuracy | 0.11 pH | |
Resolution | 0.01 pH | |
Iron | ||
Measuring range | 0.00 … 0.20 mg/l 0.20 … 0.60 mg/l 0.60 … 1.00 mg/l | |
Accuracy | 0.02 mg/l 0.04 mg/l 0.08 mg/l | |
Resolution | 0.01 mg/l | |
Cyanuric Acid | ||
Measuring range | 0 … 15 mg/l 15 … 50 mg/l 50 … 120 mg/l 120 … 160 mg/l | |
Accuracy | 1 mg/l 5 mg/l 13 mg/l 19 mg/l | |
Resolution | 1 mg/l | |
Bromine | ||
Measuring range | 0.0 … 2.5 mg/l 2.5 … 6.5 mg/l 6.5 … 11.0 mg/l 11.0 … 13.5 mg/l | |
Accuracy | 0.2 mg/l 0.6 mg/l 1.7 mg/l 2.3 mg/l | |
Resolution | 0.1 mg/l | |
Iodine | ||
Measuring range | 0.0 … 5.0 mg/l 5.1 … 10.0 mg/l 10.1 … 15.0 mg/l 15.1 … 21.4 mg/l | |
Accuracy | 0.5 mg/l 0.8 mg/l 2.7 mg/l 3.6 mg/l | |
Resolution | 0.1 mg/l | |
Further Specification | ||
Units | mg/l, ppm | |
Calibration | Zero point calibration | |
Light source | 503 nm / 570 nm / 620 nm LED | |
Light detector | Photodiode | |
Power supply | 4 x 1.5V AA batteries | |
Dimensions of the cuvette | 36 x ø 21 mm / 3.6 x ø 2.1 cm (10 ml) | |
Menu languages | English, German, French, Spanish and Italian | |
Storage | Automatic storage of measured values and readout | |
Storage space | 256 values | |
Interface | Bluetooth connection with app and PC software | |
Automatic shutdown | After 300 seconds of inactivity | |
Operating conditions | 5… 45 °C, 20 ... 90% RH non-condensing | |
Storage conditions | 5… 45 °C, 20 ... 90% RH non-condensing | |
Dimensions | 165 x 95 x 50 mm / 6.5 x 3.7 x 2 in | |
Weight | 230 g / 8.1 oz |